GB
2122740.01
3. Specications / 4. Design and function
For further specications see the corresponding product label, WIKA data sheet
and the order documentation.
Electrical contact
Type of contact Micro switch
Contact functions Single (change-over) contact
850.3
Double (change-over) contact
850.3.3
Load data Voltage AC Voltage DC
U max. 250 V 30 V
I max. 5 A 0.4 A
P max. 250 VA 10 W
Switch point setting from the outside at assistant scale by means of adjustment
screw(s)
Setting range from 10 % to 100 % of the full scale value
Switch point
reproducibility
≤ 1.6 %
Switch hysteresis max. 5 % of the full scale value (option: max. 2.5 %)
Electrical connection via cable gland M20 x 1.5 with 1 m free cable end
WIKA operating instructions dierential pressure gauge, model 702.03.100 9
2367781.03 06/2013 GB/D/F/E
4. Design and function
4.1 Description
The ⊕ and ⊖ media chambers
are separated by an elastic dia-
phragm. The dierential pres-
sure leads to an axial deection
of the the diaphragm against
the measuring range spring.
The deection, which is
proportional to the dierential
pressure, is transmitted to
a movement and in addition
to the plungers of the micro
switches via a pressure-tight
and low friction link.
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.