Wika TR12-M Uživatelský manuál Strana 14

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 13
GB
14064370.01 08/2013 GB/D
WIKA operating instructions models TR12, TC1214
Connection head, selectable (example)
Thread
Tightening torques in Nm
Connection head material
Aluminium Stainless steel
1/2 NPT 32 35
3/4 NPT 36 40
M20 x 1.5, with counter nut
1)
23 25
M24 x 1.5, with counter nut
1)
27 30
1) only for versions with non-divisible neck tube
Tightening torques between connection head and neck tube
Tightening torques for connection to thermowell
Tightening torques for connection to neck tube
Thread Tightening torques in Nm
R 1/2
1)
50 ... 60
1) only for versions with “nipple-union-nipple” neck tube
Thread
Tightening torques in Nm
1/2 NPT 35
3/4 NPT 40
G 1/2 B 35
G 3/4 B 40
M14 x 1.5 25 ... 30
M18 x 1.5 35
M20 x 1.5 35 ... 40
M27 x 2 40 ... 45
Only ever screw in, or unscrew, the instrument via the spanner-ats and to the prescribed
torque using an appropriate tool.
The correct torque depends on the dimensions of the connection thread and the gasket
used (form/material).
When screwing in or unscrewing the instrument, do not use the connection head as
contact surface.
When screwing in the instrument, please observe that the threads are not skewed.
4.6 Scope of delivery
Cross-check scope of delivery with delivery note.
4.4 Housing- and connection heads
The dimensions of the housing and connection heads are given in the respective data sheet.
4.5 Tightening torques
4. Design and function