WIKA operating instructions pressure gauge model PGS with reed contacts
GB
14
14000322.01 03/2011 GB/D/F/E
Contact
Contact
Switching voltage
Switching current
max. current
max. voltage
limit curve
allowed working
range
Vmax
Amax
A
V
7. Contact protection measures
7.3. Capacitive load
With capacitive loads elevated switch-on currents arise. These can be
reduced by series-connecting resistors in the supply line.
Examples:
Contact protec-
tion measure with
current-limiting
resistor
Contact curve
The hatched area of the contact curve shows the permissible electrical
values for the respective contact.
Accordingly the voltage and/or current to be switched must not exceed
the respective maximum values.
The power to be switched may only lie below the limit curve.