Wika S-20 Uživatelský manuál Strana 13

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 96
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 12
13WIKA operating instructions pressure transmitter, model S-20
14043170.02 07/2014 GB/D/F/E
GB
3. Specications
Electrical connections
Electrical connection Ingress
protection
2)
Wire cross-
section
Cable ∅ Cable
material
Permissible temperature
Angular connector DIN EN 175301-803 A
with mating connector IP 65 max. 1.5 mm² 6 ... 8 mm - -30 ... +100 °C
(-22 ... +212 °F)
with mating connector (conduit) IP 65 max. 1.5 mm² - - -30 ... +100 °C
(-22 ... +212 °F)
with mating connector with
moulded cable
IP 65 3 x 0.75 mm² 6 mm PUR -30 ... +100 °C (cULus: -25 ... +85 °C)
(-22 ... +212 °F (cULus: -4 ... +185 °F))
with mating connector with
moulded cable, shielded
IP 65 6 x 0.5 mm² 6.8 mm PUR -25 ... +85 °C
(-4 ... +185 °F)
Angular connector DIN EN 175301-803 C
with mating connector IP 65 max. 0.75 mm² 4.5 ... 6
mm
- -30 ... +100 °C (-22 ... +212 °F)
with mating connector with
moulded cable
IP 65 4 x 0.5 mm² 6.2 mm PUR -25 ... +85 °C
(-4 ... +185 °F)
Bayonet connector (6-pin)
IP 67 - - - -40 ... +125 °C
(-40 ... +257 °F)
Circular connector M12 x 1 (4-pin)
without mating connector IP 67 - - - -30 ... +100 °C
(-22 ... +212 °F)
with mating connector, straight
,
with moulded cable
IP 67 3 x 0.34 mm² 4.3 mm PUR -25 ... +80 °C
(-4 ... +176 °F)
with mating connector, straight,
with moulded cable, shielded
IP 67 3 x 0.34 mm² 4.3 mm PUR -25 ... +80 °C
(-4 ... +176 °F)
with mating connector, angled, with
moulded cable
IP 67 3 x 0.34 mm² 5.5 mm PUR -25 ... +80 °C
(-4 ... +176 °F)
2) Only applies when plugged in using a suitable mating connector that has the appropriate ingress protection