Specifications Model WU-1X
WU-10 / WU-15
WU-16
Pressure ranges bar 4 7 10 16 25 40 60 100 160 250 400
psi 60 100 160 250 300 500 1000 1500 2000 3000 5000
Over pressure safety
1)
bar 8 14 20 32 50 80 120 200 320 500 500
Burst pressure
1)
bar 40 70 100 160 250 400 550 720 720 720 720
Other pressure ranges and pressure units (e.g. MPa, kg/cm
2
) on request
1)
1 bar = 14.50 psi
Measuring principle Metal thin-film sensor
Materials
Wetted parts 2.4711 Elgiloy
®
(Sensor); 316L VIM/VAR (Pressure connection)
Case Stainless steel
Surface finish Electropolished, typical
Ra 0.18 µm (RA 7); Ra max 0.25 µm (RA 10)
Dead volume WU-10 < 1500, WU-15 < 1000, WU-16 < 1000
Permissible Medium Liquid / Gas / Vapour
Power supply U
B UB in VDC
10 < U
B 30 (14 ... 30 V with output signal 0.1 ... 10.1 V and 0...10 V)
Capacitive load µF Max. 0.1 (Voltage output)
Max. current output mA < 1 Voltage output; Source
mA < 30 Current output
Adjustability zero % of span ± 5 via potentiometer
Response time (10 ... 90 %) ms
2
Dielectric strength VDC 500
Accuracy % of span
0.25 for pressure ranges > 4 bar (BFSL)
% of span
0.5 for pressure ranges 4 bar (BFSL)
% of span
0.5
2)
for pressure ranges > 4 bar
% of span
1.0
2)
for pressure ranges 4 bar
Specifications Model WU-1X
2)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.
Non-linearity % of span
0.15 for pressure ranges > 4 bar (BFSL) according to IEC 61298-2
% of span
0.3 for pressure ranges 4 bar (BFSL) according to IEC 61298-2
1-year stability % of span
0.2 (at reference conditions)
Permissible temperature of
Medium -40 ... +100 °C -40 ... +212 °F
Ambience -20 ... +85 °C -4 ... +185 °F
Storage -40 ... +100 °C -40 ... +212 °F
Compensated temp range -20 ... +80 °C -4 ... +176 °F
Temperature coefficients within
compensated temp range
Mean TC of zero % of span
0.1 / 10 K
Mean TC of range % of span
0.15 / 10 K
CE- conformitiy
Pressure equipment directive 97/23/EC
EMC directive
2004/108/EC, EN 61 326 Emission (Group 1, Class B) and
Immunity (industrial locations)
Directive ATEX of equipment
intended for use in potentially
explosive atmospheres
94/9/EC
Shock resistance g 500 according to IEC 60068-2-27 (mechanical shock)
Vibration resistance g 10 according to IEC 60068-2-6 (vibration under resonance)
Wiring protection
Short-circuit proofness Sig+ towards U
B- (short-time)
Reverse polarity protection U
B+ towards UB-
Weight kg Approx. 0.1
7. Starting, operation
GB
7. Starting, operation
GB