GB
11178648.04 03/2010 GB/D/F/E
8 WIKA Operating Instructions Temperature Transmitter T53
2.3.1 Conditions for Model T53.10.0NI from type examination
certicate KEMA 06ATEX149 X
Zone 2 approval II 3 GD Ex nA [nL] IIC T4 ... T6
II 3 GD Ex nL IIC T4 ... T6
II 3 GD Ex nA [ic] IIC T4 ... T6
II 3 GD Ex ic IIC T4 ... T6
Entity parameters:
T53.10.0NI
Zone 2 Ex nL IIC/
Ex ic IIC
Zone 2 nA FNICO (FISCO)
U
i
32 VDC 32 VDC 17.5 VDC
L
i
1 µH 1 µH
C
i
2.0 nF 2.0 nF
T1 ... T4 T
a
≤ 85 °C T
a
≤ 85 °C T
a
≤ 85 °C
T5 T
a
≤ 75 °C T
a
≤ 75 °C T
a
≤ 75 °C
T6 T
a
≤ 60 °C T
a
≤ 60 °C T
a
≤ 60 °C
Sensor (terminal 3, 4, 5 and 6):
Uo : 5.7 VDC
Io : 8.4 mA
Po : 12 mW
Lo : 200 mH
Co : 40 µF
Specic conditions for safe use
For use in potentially explosive atmosphere of ammable gasses,
vapours or mists, the transmitter T53.10.0NI shall be mounted in an
enclosure providing a degree of protection of at least IP 54 in accord-
ance with EN 60 529.
For use in the presence of combustible dusts, the transmitter shall be
mounted in an enclosure providing a degree of protection of at least
IP 6X in accordance with EN 60 529. The surface temperature of the
enclosure shall be determined after installation of the transmitter.
2. Safety
Komentáře k této Příručce