Wika DPT-10 Uživatelský manuál Strana 29

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 96
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 28
8 Oval ange adapter
9 Fixing screws
4.8 External housing
1 Mark the holes according to the following drilling template
2 Depending on the mounting surface, fasten the wall mounting
plate with 4 screws
90 mm (3.54")
R3,5 mm
(0.14")
3 mm
(0.12")
70 mm (2.76")
8 mm
(0.32")
93 mm (3.66")
110 mm (4.33")
Fig. 27: Drilling template - wall mounting plate
Mount the wall mounting plate so that the cable entry of the socket
housing points downward. The socket housing can be displaced by
180° to the wall mounting plate.
4.9 Mounting control
Check the following after mounting the instrument:
l Did you tighten all screws?
l Closing screws and ventilation valves closed
Wall mounting
Dierential pressure transmitter DPT10 - metal measuring diaphragm Probus PA 29
4 Mounting
37245-EN-100120
Zobrazit stránku 28